{"id":368,"date":"2024-12-17T10:00:00","date_gmt":"2024-12-17T09:00:00","guid":{"rendered":"https:\/\/network360.fr\/?p=368"},"modified":"2025-02-14T09:37:49","modified_gmt":"2025-02-14T08:37:49","slug":"upgrade-ise-3-2-vers-3-3-cli","status":"publish","type":"post","link":"https:\/\/network360.fr\/index.php\/2024\/12\/17\/upgrade-ise-3-2-vers-3-3-cli\/","title":{"rendered":"Upgrade &#8211; ISE 3.2 vers 3.3 &#8211; CLI"},"content":{"rendered":"\n<p>Sur Cisco Dcloud (Ici : <a href=\"https:\/\/dcloud.cisco.com\/\">https:\/\/dcloud.cisco.com\/)<\/a>, vous pouvez r\u00e9server un serveur Cisco ISE. <\/p>\n\n\n\n<p>C&rsquo;est ce que j&rsquo;ai fait pour tester un upgrade de la version 3.2 vers la version 3.3 en CLI. <\/p>\n\n\n\n<p>La mise \u00e0 jour a dur\u00e9 1h30 au total. Le temps peut \u00eatre plus important si vous avez beaucoup de logs dans le serveur ISE. <\/p>\n\n\n\n<p>Pour la mise \u00e0 jour, j&rsquo;ai fais deux prises de logs : <\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>La sortie de ma session SSH<\/li>\n\n\n\n<li>Un show logging system ade\/ADE.log tail<\/li>\n<\/ul>\n\n\n\n<p><\/p>\n\n\n\n<p>Pour faire l&rsquo;upgrade il faut : <\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Avoir configur\u00e9 un repository (Pas pr\u00e9sent\u00e9 ici)<\/li>\n\n\n\n<li>Avoir mis les fichiers de mise \u00e0 jour dans le repository (Pour moi c&rsquo;\u00e9tait un FTP avec Filezilla)<\/li>\n<\/ul>\n\n\n\n<p><\/p>\n\n\n\n<p>En cli, on peut voir s&rsquo;il y a d\u00e9j\u00e0 un repo et ce qu&rsquo;il y a dedans<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>show running-config repository \nshow repository FTP <\/code><\/pre>\n\n\n\n<p>La mise \u00e0 jour se fait en deux commandes <\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>La pr\u00e9paration : L&rsquo;ISE t\u00e9l\u00e9charge le fichier, le d\u00e9compresse et v\u00e9rifie sa signature. <\/li>\n\n\n\n<li>Le lancement : L&rsquo;ISE effectue la mise \u00e0 jour. <\/li>\n<\/ul>\n\n\n\n<p><\/p>\n\n\n\n<pre class=\"wp-block-code\"><code><strong>application upgrade prepare ise-upgradebundle-3.0.x-3.2.x-to-3.3.0.430b.SPA.x86_64.tar.gz FTP<\/strong>\n<strong>application upgrade proceed<\/strong> <\/code><\/pre>\n\n\n\n<p>Voici les logs de la mise \u00e0 jour <\/p>\n\n\n\n<p>Ps : En gras, les commandes que j&rsquo;ai tap\u00e9<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>=~=~=~=~=~=~=~=~=~=~=~= PuTTY log 2024.12.09 15:12:40 =~=~=~=~=~=~=~=~=~=~=~=\n<strong>show running-config repository \n<\/strong>repository FTP\n url ftp: \/\/198.18.133.36\/\n user ise password hash **********\n!\nise\/admin#<strong>show repository FTP<\/strong>\ndesktop.ini                                                                                         \nise-patchbundle-3.3.0.430-Patch3-24070910.SPA.x86_64.tar.gz                                         \nise-upgradebundle-3.0.x-3.2.x-to-3.3.0.430b.SPA.x86_64.tar.gz                                       \nShareX-16.1.0-setup.exe                                                                             \nise\/admin#<strong>screen-length 0<\/strong>\nise\/admin#<strong>application upgrade prepare ise-upgradebundle-3.0.x-3.2.x-to-3.3.0.430b.SPA.x86_64.tar.gz FTP\n<\/strong>Be sure that all your software is working stable, check your system on UI page (Administration > System > Health Checks) \nType yes once confirmed that health of the system is good to proceed:  (yes\/no) &#91;yes] ? <strong>yes<\/strong>\n\nBe sure that all your software is working stable, check your system on UI page (Administration > System > Health Checks) \n\nGetting bundle to local machine...\nUnbundling Application Package...\nVerifying Application Signature..\n\nApplication upgrade preparation successful\n\nise\/admin#<strong>application upgrade proceed<\/strong> \nInitiating Application Upgrade...\n% Warning: Do not use Ctrl-C or close this terminal window until upgrade completes.\n-Checking VM for minimum hardware requirements\nRequired ESX Version 7.0 available to proceed with upgrade\nSTEP 1: Stopping ISE application...\nSTEP 2: Verifying files in bundle...\n-Internal hash verification passed for bundle\nSTEP 3: Validating data before upgrade...\nSTEP 4: Taking backup of the configuration data...\nTruncating sec_txnlog_master - STANDALONE...\nSTEP 5: Running ISE configuration database schema upgrade...\n- Running db sanity to check and fix if any index corruption\n- Auto Upgrading Schema for UPS Model\n- Upgrading Schema completed for UPS Model\nISE database schema upgrade completed.\nSTEP 6: Running ISE configuration data upgrade...\n- Data upgrade step 1\/24, AuthzPolicyDictionaryManager(3.3.0.108)... Done in 5 seconds.\n- Data upgrade step 2\/24, PIProfilerRegistrationService(3.3.0.140)... Done in 11 seconds.\n- Data upgrade step 3\/24, MfcDictionaryManager(3.3.0.188)... Done in 0 seconds.\n- Data upgrade step 4\/24, NSFUpgradeService(3.3.0.250)... Done in 0 seconds.\n- Data upgrade step 5\/24, IdentityProviderAddCertToTrustedListUpgrade(3.3.0.253)... Done in 0 seconds.\n- Data upgrade step 6\/24, PostureSessionOSArchRegistration(3.3.0.257)... Done in 0 seconds.\n- Data upgrade step 7\/24, ProfilerUpgradeService(3.3.0.286)... Done in 0 seconds.\n- Data upgrade step 8\/24, CertMgmtUpgradeService(3.3.0.295)... Done in 0 seconds.\n- Data upgrade step 9\/24, UPSUpgradeHandler(3.3.0.295)... Done in 5 seconds.\n- Data upgrade step 10\/24, PIProfilerRegistrationService(3.3.0.306)... Done in 0 seconds.\n- Data upgrade step 11\/24, CpmIpFilterUpgradeService(3.3.0.306)... Done in 0 seconds.\n- Data upgrade step 12\/24, NodeExporterPasswordHandler(3.3.0.356)... Done in 34 seconds.\n- Data upgrade step 13\/24, ProfilerUpgradeService(3.3.0.365)... Done in 0 seconds.\n- Data upgrade step 14\/24, PIProfilerRegistrationService(3.3.0.400)... Done in 0 seconds.\n- Data upgrade step 15\/24, LogAnalyticsEnableService(3.3.0.417)... ..Done in 135 seconds.\n- Data upgrade step 16\/24, NSFUpgradeService(3.3.0.430)... Done in 0 seconds.\n- Data upgrade step 17\/24, ProfilerUpgradeService(3.3.0.430)... Done in 0 seconds.\n- Data upgrade step 18\/24, GuestAccessUpgradeService(3.3.0.430)... Done in 9 seconds.\n- Data upgrade step 19\/24, UPSUpgradeHandler(3.3.0.430)... Done in 2 seconds.\n- Data upgrade step 20\/24, ESUpgradeService(3.3.0.430)... .Done in 105 seconds.\n- Data upgrade step 21\/24, ProvisioningRegistrationNew(3.3.0.430)... Done in 0 seconds.\n- Data upgrade step 22\/24, NodeExporterPasswordHandler(3.3.0.430)... Done in 0 seconds.\n- Data upgrade step 23\/24, LogAnalyticsEnableService(3.3.0.430)... Done in 8 seconds.\n- Data upgrade step 24\/24, SecuritySettingsRegistration(3.3.0.464)... Done in 0 seconds.\nSTEP 7: Running ISE configuration data upgrade for node specific data...\nSTEP 8: Running ISE M&amp;T database upgrade...\nM&amp;T Log Processor is not running\nISE database M&amp;T schema upgrade completed.\n% Warning: Some warnings encountered during MNT sanity check\nDeleting stale upgradedb property files , if any.\n% NOTICE: The appliance will reboot twice to upgrade software and ADE-OS. During this time progress of the upgrade is visible on console. It could take up to 30 minutes for this to complete.\nRebooting to do Identity Service Engine upgrade...\n\nApplication upgrade successful\nise\/admin#\n<\/code><\/pre>\n\n\n\n<p>A ce moment, le serveur ISE s&rsquo;\u00e9teint et il red\u00e9marre deux fois.<\/p>\n\n\n\n<p> (% NOTICE: The appliance will reboot twice to upgrade software and ADE-OS. During this time progress of the upgrade is visible on console. It could take up to 30 minutes for this to )<\/p>\n\n\n\n<p>Il faut simplement patienter le temps que l&rsquo;ISE revienne. <\/p>\n\n\n\n<p>Ci-dessous la suite, une fois revenu<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>ise\/admin#<strong>show application status ise<\/strong>\n\n% Application status information is not available\n\nise\/admin#<strong>show application status ise<\/strong>\n\n% Application ise is not installed\n\nise\/admin#<strong>show application status ise<\/strong>\n\n% NOTICE: Identity Services Engine upgrade is in progress...\n\nise\/admin#<strong>show application status ise<\/strong>\nISE PROCESS NAME                       STATE            PROCESS ID  \n\n--------------------------------------------------------------------\n\nDatabase Listener                      running          91956       \n\nDatabase Server                        running          127 PROCESSES\n\nApplication Server                     running          112060      \n\nProfiler Database                      running          100447      \n\nISE Indexing Engine                    running          112866      \n\nAD Connector                           running          114131      \n\nM&amp;T Session Database                   running          101281      \n\nM&amp;T Log Processor                      running          112228      \n\nCertificate Authority Service          running          114001      \n\nEST Service                            running          161535      \n\nSXP Engine Service                     disabled                     \n\nTC-NAC Service                         disabled        \n\nPassiveID WMI Service                  disabled                     \n\nPassiveID Syslog Service               disabled                     \n\nPassiveID API Service                  disabled                     \n\nPassiveID Agent Service                disabled                     \n\nPassiveID Endpoint Service             disabled                     \n\nPassiveID SPAN Service                 disabled                     \n\nDHCP Server (dhcpd)                    disabled                     \n\nDNS Server (named)                     disabled                     \n\nISE Messaging Service                  running          94913       \n\nISE API Gateway Database Service       running          97202       \n\nISE API Gateway Service                running          176020      \n\nISE pxGrid Direct Service              running          149686      \n\nSegmentation Policy Service            disabled                     \n\nREST Auth Service                      disabled                     \n\nSSE Connector                          disabled                     \n\nHermes (pxGrid Cloud Agent)            disabled                     \n\nMcTrust (Meraki Sync Service)          disabled                     \n\nISE Node Exporter                      running          115182      \n\nISE Prometheus Service                 running          117426      \n\nISE Grafana Service                    running          126562      \n\nISE MNT LogAnalytics Elasticsearch     initializing                 \n\nISE Logstash Service                   not running                  \n\nISE Kibana Service                     not running                  \n\nISE Native IPSec Service               running          145871      \n\nMFC Profiler                           running          155447      \n\nise\/admin#<strong>show version<\/strong>\n\nCisco Application Deployment Engine OS Release: 3.3\n\nADE-OS Build Version: 3.3.0.181\n\nADE-OS System Architecture: x86_64\n\nCopyright (c) 2005-2023 by Cisco Systems, Inc.\n\nAll rights reserved.\n\nHostname: ise\n\nVersion information of installed applications\n\n---------------------------------------------\n\nCisco Identity Services Engine\n\n---------------------------------------------\n\nVersion      : 3.3.0.430\n\nBuild Date   : Tue Jul  4 00:31:18 2023\n\nInstall Date : Mon Dec  9 16:12:36 2024\n\nise\/admin#<\/code><\/pre>\n\n\n\n<p class=\"has-text-align-center\"><strong>Et voil\u00e0 ! <\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" width=\"1024\" height=\"1024\" data-src=\"https:\/\/network360.fr\/wp-content\/uploads\/2024\/12\/happy_update.webp\" alt=\"\" class=\"wp-image-373 lazyload\" style=\"--smush-placeholder-width: 1024px; --smush-placeholder-aspect-ratio: 1024\/1024;width:484px;height:auto\" data-srcset=\"https:\/\/network360.fr\/wp-content\/uploads\/2024\/12\/happy_update.webp 1024w, https:\/\/network360.fr\/wp-content\/uploads\/2024\/12\/happy_update-300x300.webp 300w, https:\/\/network360.fr\/wp-content\/uploads\/2024\/12\/happy_update-150x150.webp 150w, https:\/\/network360.fr\/wp-content\/uploads\/2024\/12\/happy_update-768x768.webp 768w, https:\/\/network360.fr\/wp-content\/uploads\/2024\/12\/happy_update-600x600.webp 600w, https:\/\/network360.fr\/wp-content\/uploads\/2024\/12\/happy_update-100x100.webp 100w\" data-sizes=\"(max-width: 1024px) 100vw, 1024px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" \/><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p>Bien \u00e9videment, en production, on effectue une batterie de test (AD, 802.1X, Tacacs, Failover etc&#8230;)<\/p>\n\n\n\n<p><\/p>\n\n\n\n<p>Ci-dessous, les logs entier de la mise \u00e0 jour. Ca peut servir de comparatif ! <\/p>\n\n\n\n<div class=\"wp-block-file\"><a id=\"wp-block-file--media-6bf02df2-4cf9-40e8-96a5-58808ce4b20f\" href=\"https:\/\/network360.fr\/wp-content\/uploads\/2024\/12\/INSTALL_ADE-FULL.txt\">INSTALL_ADE-FULL<\/a><a href=\"https:\/\/network360.fr\/wp-content\/uploads\/2024\/12\/INSTALL_ADE-FULL.txt\" class=\"wp-block-file__button wp-element-button\" download aria-describedby=\"wp-block-file--media-6bf02df2-4cf9-40e8-96a5-58808ce4b20f\">T\u00e9l\u00e9charger<\/a><\/div>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Mise \u00e0 jour d&rsquo;un ISE de la version 3.2 vers la 3.3<\/p>\n","protected":false},"author":1,"featured_media":588,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[23],"tags":[36,28,29,30],"class_list":["post-368","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-upgrade","tag-3-3","tag-cisco","tag-ise","tag-upgrade"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Upgrade - ISE 3.2 vers 3.3 - CLI - Network360<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/network360.fr\/index.php\/2024\/12\/17\/upgrade-ise-3-2-vers-3-3-cli\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Upgrade - ISE 3.2 vers 3.3 - CLI - Network360\" \/>\n<meta property=\"og:description\" content=\"Mise \u00e0 jour d&#039;un ISE de la version 3.2 vers la 3.3\" \/>\n<meta property=\"og:url\" content=\"https:\/\/network360.fr\/index.php\/2024\/12\/17\/upgrade-ise-3-2-vers-3-3-cli\/\" \/>\n<meta property=\"og:site_name\" content=\"Network360\" \/>\n<meta property=\"article:published_time\" content=\"2024-12-17T09:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-02-14T08:37:49+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/i0.wp.com\/network360.fr\/wp-content\/uploads\/2025\/02\/gb3d90cdea6943e2dda980f85788deb68d1984f65125d2ee94725f65fb38ad9d3b72f7fa855438bd5e8c638ce94fd4aa7_640-90389.jpg?fit=640%2C427&ssl=1\" \/>\n\t<meta property=\"og:image:width\" content=\"640\" \/>\n\t<meta property=\"og:image:height\" content=\"427\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/network360.fr\\\/index.php\\\/2024\\\/12\\\/17\\\/upgrade-ise-3-2-vers-3-3-cli\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/network360.fr\\\/index.php\\\/2024\\\/12\\\/17\\\/upgrade-ise-3-2-vers-3-3-cli\\\/\"},\"author\":{\"name\":\"Admin\",\"@id\":\"https:\\\/\\\/network360.fr\\\/#\\\/schema\\\/person\\\/0f765d2aa5031b9c6e0ff879e9622f00\"},\"headline\":\"Upgrade &#8211; ISE 3.2 vers 3.3 &#8211; CLI\",\"datePublished\":\"2024-12-17T09:00:00+00:00\",\"dateModified\":\"2025-02-14T08:37:49+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/network360.fr\\\/index.php\\\/2024\\\/12\\\/17\\\/upgrade-ise-3-2-vers-3-3-cli\\\/\"},\"wordCount\":288,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/network360.fr\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/network360.fr\\\/index.php\\\/2024\\\/12\\\/17\\\/upgrade-ise-3-2-vers-3-3-cli\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/network360.fr\\\/wp-content\\\/uploads\\\/2025\\\/02\\\/gb3d90cdea6943e2dda980f85788deb68d1984f65125d2ee94725f65fb38ad9d3b72f7fa855438bd5e8c638ce94fd4aa7_640-90389.jpg\",\"keywords\":[\"3.3\",\"Cisco\",\"ISE\",\"UPGRADE\"],\"articleSection\":[\"Upgrade\"],\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/network360.fr\\\/index.php\\\/2024\\\/12\\\/17\\\/upgrade-ise-3-2-vers-3-3-cli\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/network360.fr\\\/index.php\\\/2024\\\/12\\\/17\\\/upgrade-ise-3-2-vers-3-3-cli\\\/\",\"url\":\"https:\\\/\\\/network360.fr\\\/index.php\\\/2024\\\/12\\\/17\\\/upgrade-ise-3-2-vers-3-3-cli\\\/\",\"name\":\"Upgrade - ISE 3.2 vers 3.3 - CLI - Network360\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/network360.fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/network360.fr\\\/index.php\\\/2024\\\/12\\\/17\\\/upgrade-ise-3-2-vers-3-3-cli\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/network360.fr\\\/index.php\\\/2024\\\/12\\\/17\\\/upgrade-ise-3-2-vers-3-3-cli\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/network360.fr\\\/wp-content\\\/uploads\\\/2025\\\/02\\\/gb3d90cdea6943e2dda980f85788deb68d1984f65125d2ee94725f65fb38ad9d3b72f7fa855438bd5e8c638ce94fd4aa7_640-90389.jpg\",\"datePublished\":\"2024-12-17T09:00:00+00:00\",\"dateModified\":\"2025-02-14T08:37:49+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/network360.fr\\\/index.php\\\/2024\\\/12\\\/17\\\/upgrade-ise-3-2-vers-3-3-cli\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/network360.fr\\\/index.php\\\/2024\\\/12\\\/17\\\/upgrade-ise-3-2-vers-3-3-cli\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/network360.fr\\\/index.php\\\/2024\\\/12\\\/17\\\/upgrade-ise-3-2-vers-3-3-cli\\\/#primaryimage\",\"url\":\"https:\\\/\\\/network360.fr\\\/wp-content\\\/uploads\\\/2025\\\/02\\\/gb3d90cdea6943e2dda980f85788deb68d1984f65125d2ee94725f65fb38ad9d3b72f7fa855438bd5e8c638ce94fd4aa7_640-90389.jpg\",\"contentUrl\":\"https:\\\/\\\/network360.fr\\\/wp-content\\\/uploads\\\/2025\\\/02\\\/gb3d90cdea6943e2dda980f85788deb68d1984f65125d2ee94725f65fb38ad9d3b72f7fa855438bd5e8c638ce94fd4aa7_640-90389.jpg\",\"width\":640,\"height\":427,\"caption\":\"server, room, datacenter, network, leds, night, datacenter, datacenter, datacenter, datacenter, datacenter\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/network360.fr\\\/index.php\\\/2024\\\/12\\\/17\\\/upgrade-ise-3-2-vers-3-3-cli\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\\\/\\\/network360.fr\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Upgrade &#8211; ISE 3.2 vers 3.3 &#8211; CLI\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/network360.fr\\\/#website\",\"url\":\"https:\\\/\\\/network360.fr\\\/\",\"name\":\"Network360\",\"description\":\"Network360.FR | Boostez votre carri\u00e8re r\u00e9seau : CCNA, Cisco, Automation |\",\"publisher\":{\"@id\":\"https:\\\/\\\/network360.fr\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/network360.fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/network360.fr\\\/#organization\",\"name\":\"Network360\",\"url\":\"https:\\\/\\\/network360.fr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/network360.fr\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/i0.wp.com\\\/network360.fr\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/cropped-LOGO3-3_preview_rev_1-1.png?fit=501%2C410&ssl=1\",\"contentUrl\":\"https:\\\/\\\/i0.wp.com\\\/network360.fr\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/cropped-LOGO3-3_preview_rev_1-1.png?fit=501%2C410&ssl=1\",\"width\":501,\"height\":410,\"caption\":\"Network360\"},\"image\":{\"@id\":\"https:\\\/\\\/network360.fr\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/network360.fr\\\/#\\\/schema\\\/person\\\/0f765d2aa5031b9c6e0ff879e9622f00\",\"name\":\"Admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/268fa79373fa3d1db9782a1cda40eca20b34e670aede3da90a8fb05b69521bbd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/268fa79373fa3d1db9782a1cda40eca20b34e670aede3da90a8fb05b69521bbd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/268fa79373fa3d1db9782a1cda40eca20b34e670aede3da90a8fb05b69521bbd?s=96&d=mm&r=g\",\"caption\":\"Admin\"},\"sameAs\":[\"https:\\\/\\\/network360.fr\"],\"url\":\"https:\\\/\\\/network360.fr\\\/index.php\\\/author\\\/netadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Upgrade - ISE 3.2 vers 3.3 - CLI - Network360","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/network360.fr\/index.php\/2024\/12\/17\/upgrade-ise-3-2-vers-3-3-cli\/","og_locale":"fr_FR","og_type":"article","og_title":"Upgrade - ISE 3.2 vers 3.3 - CLI - Network360","og_description":"Mise \u00e0 jour d'un ISE de la version 3.2 vers la 3.3","og_url":"https:\/\/network360.fr\/index.php\/2024\/12\/17\/upgrade-ise-3-2-vers-3-3-cli\/","og_site_name":"Network360","article_published_time":"2024-12-17T09:00:00+00:00","article_modified_time":"2025-02-14T08:37:49+00:00","og_image":[{"width":640,"height":427,"url":"https:\/\/i0.wp.com\/network360.fr\/wp-content\/uploads\/2025\/02\/gb3d90cdea6943e2dda980f85788deb68d1984f65125d2ee94725f65fb38ad9d3b72f7fa855438bd5e8c638ce94fd4aa7_640-90389.jpg?fit=640%2C427&ssl=1","type":"image\/jpeg"}],"author":"Admin","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"Admin","Dur\u00e9e de lecture estim\u00e9e":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/network360.fr\/index.php\/2024\/12\/17\/upgrade-ise-3-2-vers-3-3-cli\/#article","isPartOf":{"@id":"https:\/\/network360.fr\/index.php\/2024\/12\/17\/upgrade-ise-3-2-vers-3-3-cli\/"},"author":{"name":"Admin","@id":"https:\/\/network360.fr\/#\/schema\/person\/0f765d2aa5031b9c6e0ff879e9622f00"},"headline":"Upgrade &#8211; ISE 3.2 vers 3.3 &#8211; CLI","datePublished":"2024-12-17T09:00:00+00:00","dateModified":"2025-02-14T08:37:49+00:00","mainEntityOfPage":{"@id":"https:\/\/network360.fr\/index.php\/2024\/12\/17\/upgrade-ise-3-2-vers-3-3-cli\/"},"wordCount":288,"commentCount":0,"publisher":{"@id":"https:\/\/network360.fr\/#organization"},"image":{"@id":"https:\/\/network360.fr\/index.php\/2024\/12\/17\/upgrade-ise-3-2-vers-3-3-cli\/#primaryimage"},"thumbnailUrl":"https:\/\/network360.fr\/wp-content\/uploads\/2025\/02\/gb3d90cdea6943e2dda980f85788deb68d1984f65125d2ee94725f65fb38ad9d3b72f7fa855438bd5e8c638ce94fd4aa7_640-90389.jpg","keywords":["3.3","Cisco","ISE","UPGRADE"],"articleSection":["Upgrade"],"inLanguage":"fr-FR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/network360.fr\/index.php\/2024\/12\/17\/upgrade-ise-3-2-vers-3-3-cli\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/network360.fr\/index.php\/2024\/12\/17\/upgrade-ise-3-2-vers-3-3-cli\/","url":"https:\/\/network360.fr\/index.php\/2024\/12\/17\/upgrade-ise-3-2-vers-3-3-cli\/","name":"Upgrade - ISE 3.2 vers 3.3 - CLI - Network360","isPartOf":{"@id":"https:\/\/network360.fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/network360.fr\/index.php\/2024\/12\/17\/upgrade-ise-3-2-vers-3-3-cli\/#primaryimage"},"image":{"@id":"https:\/\/network360.fr\/index.php\/2024\/12\/17\/upgrade-ise-3-2-vers-3-3-cli\/#primaryimage"},"thumbnailUrl":"https:\/\/network360.fr\/wp-content\/uploads\/2025\/02\/gb3d90cdea6943e2dda980f85788deb68d1984f65125d2ee94725f65fb38ad9d3b72f7fa855438bd5e8c638ce94fd4aa7_640-90389.jpg","datePublished":"2024-12-17T09:00:00+00:00","dateModified":"2025-02-14T08:37:49+00:00","breadcrumb":{"@id":"https:\/\/network360.fr\/index.php\/2024\/12\/17\/upgrade-ise-3-2-vers-3-3-cli\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/network360.fr\/index.php\/2024\/12\/17\/upgrade-ise-3-2-vers-3-3-cli\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/network360.fr\/index.php\/2024\/12\/17\/upgrade-ise-3-2-vers-3-3-cli\/#primaryimage","url":"https:\/\/network360.fr\/wp-content\/uploads\/2025\/02\/gb3d90cdea6943e2dda980f85788deb68d1984f65125d2ee94725f65fb38ad9d3b72f7fa855438bd5e8c638ce94fd4aa7_640-90389.jpg","contentUrl":"https:\/\/network360.fr\/wp-content\/uploads\/2025\/02\/gb3d90cdea6943e2dda980f85788deb68d1984f65125d2ee94725f65fb38ad9d3b72f7fa855438bd5e8c638ce94fd4aa7_640-90389.jpg","width":640,"height":427,"caption":"server, room, datacenter, network, leds, night, datacenter, datacenter, datacenter, datacenter, datacenter"},{"@type":"BreadcrumbList","@id":"https:\/\/network360.fr\/index.php\/2024\/12\/17\/upgrade-ise-3-2-vers-3-3-cli\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/network360.fr\/"},{"@type":"ListItem","position":2,"name":"Upgrade &#8211; ISE 3.2 vers 3.3 &#8211; CLI"}]},{"@type":"WebSite","@id":"https:\/\/network360.fr\/#website","url":"https:\/\/network360.fr\/","name":"Network360","description":"Network360.FR | Boostez votre carri\u00e8re r\u00e9seau : CCNA, Cisco, Automation |","publisher":{"@id":"https:\/\/network360.fr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/network360.fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/network360.fr\/#organization","name":"Network360","url":"https:\/\/network360.fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/network360.fr\/#\/schema\/logo\/image\/","url":"https:\/\/i0.wp.com\/network360.fr\/wp-content\/uploads\/2024\/12\/cropped-LOGO3-3_preview_rev_1-1.png?fit=501%2C410&ssl=1","contentUrl":"https:\/\/i0.wp.com\/network360.fr\/wp-content\/uploads\/2024\/12\/cropped-LOGO3-3_preview_rev_1-1.png?fit=501%2C410&ssl=1","width":501,"height":410,"caption":"Network360"},"image":{"@id":"https:\/\/network360.fr\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/network360.fr\/#\/schema\/person\/0f765d2aa5031b9c6e0ff879e9622f00","name":"Admin","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/secure.gravatar.com\/avatar\/268fa79373fa3d1db9782a1cda40eca20b34e670aede3da90a8fb05b69521bbd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/268fa79373fa3d1db9782a1cda40eca20b34e670aede3da90a8fb05b69521bbd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/268fa79373fa3d1db9782a1cda40eca20b34e670aede3da90a8fb05b69521bbd?s=96&d=mm&r=g","caption":"Admin"},"sameAs":["https:\/\/network360.fr"],"url":"https:\/\/network360.fr\/index.php\/author\/netadmin\/"}]}},"uagb_featured_image_src":{"full":["https:\/\/network360.fr\/wp-content\/uploads\/2025\/02\/gb3d90cdea6943e2dda980f85788deb68d1984f65125d2ee94725f65fb38ad9d3b72f7fa855438bd5e8c638ce94fd4aa7_640-90389.jpg",640,427,false],"thumbnail":["https:\/\/network360.fr\/wp-content\/uploads\/2025\/02\/gb3d90cdea6943e2dda980f85788deb68d1984f65125d2ee94725f65fb38ad9d3b72f7fa855438bd5e8c638ce94fd4aa7_640-90389-150x150.jpg",150,150,true],"medium":["https:\/\/network360.fr\/wp-content\/uploads\/2025\/02\/gb3d90cdea6943e2dda980f85788deb68d1984f65125d2ee94725f65fb38ad9d3b72f7fa855438bd5e8c638ce94fd4aa7_640-90389-300x200.jpg",300,200,true],"medium_large":["https:\/\/network360.fr\/wp-content\/uploads\/2025\/02\/gb3d90cdea6943e2dda980f85788deb68d1984f65125d2ee94725f65fb38ad9d3b72f7fa855438bd5e8c638ce94fd4aa7_640-90389.jpg",640,427,false],"large":["https:\/\/network360.fr\/wp-content\/uploads\/2025\/02\/gb3d90cdea6943e2dda980f85788deb68d1984f65125d2ee94725f65fb38ad9d3b72f7fa855438bd5e8c638ce94fd4aa7_640-90389.jpg",640,427,false],"hd_qu_size2":["https:\/\/network360.fr\/wp-content\/uploads\/2025\/02\/gb3d90cdea6943e2dda980f85788deb68d1984f65125d2ee94725f65fb38ad9d3b72f7fa855438bd5e8c638ce94fd4aa7_640-90389.jpg",400,267,false],"1536x1536":["https:\/\/network360.fr\/wp-content\/uploads\/2025\/02\/gb3d90cdea6943e2dda980f85788deb68d1984f65125d2ee94725f65fb38ad9d3b72f7fa855438bd5e8c638ce94fd4aa7_640-90389.jpg",640,427,false],"2048x2048":["https:\/\/network360.fr\/wp-content\/uploads\/2025\/02\/gb3d90cdea6943e2dda980f85788deb68d1984f65125d2ee94725f65fb38ad9d3b72f7fa855438bd5e8c638ce94fd4aa7_640-90389.jpg",640,427,false]},"uagb_author_info":{"display_name":"Admin","author_link":"https:\/\/network360.fr\/index.php\/author\/netadmin\/"},"uagb_comment_info":1,"uagb_excerpt":"Mise \u00e0 jour d'un ISE de la version 3.2 vers la 3.3","_links":{"self":[{"href":"https:\/\/network360.fr\/index.php\/wp-json\/wp\/v2\/posts\/368","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/network360.fr\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/network360.fr\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/network360.fr\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/network360.fr\/index.php\/wp-json\/wp\/v2\/comments?post=368"}],"version-history":[{"count":0,"href":"https:\/\/network360.fr\/index.php\/wp-json\/wp\/v2\/posts\/368\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/network360.fr\/index.php\/wp-json\/wp\/v2\/media\/588"}],"wp:attachment":[{"href":"https:\/\/network360.fr\/index.php\/wp-json\/wp\/v2\/media?parent=368"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/network360.fr\/index.php\/wp-json\/wp\/v2\/categories?post=368"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/network360.fr\/index.php\/wp-json\/wp\/v2\/tags?post=368"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}